5db2cd7deb1259906117448268669f7

PriceList for Waste Vapor Treating Equipment For Fish Meal Plant - Fishmeal Production Line Blower – Fanxiang

Short Description:

Product Detail

Product Tags

Related Video

Feedback (2)

We purpose to understand high quality disfigurement with the output and supply the top service to domestic and overseas buyers wholeheartedly for Packing Machine , Complete Packaging System , Stick Water Tank , Your inquiry might be extremely welcomed plus a win-win prosperous development are what we've been expecting.
PriceList for Waste Vapor Treating Equipment For Fish Meal Plant - Fishmeal Production Line Blower – Fanxiang Detail:

Model

Dimensions (mm)

Power (kw)

L

W

H

9-19NO8.6C

2205

1055

1510

30

9-19NO7C

2220

770

1220

15

Y5-47NO5C

1925

830

1220

11

working principle

The vapors transportation is carried out by the Blower. The impeller with several curved fan blade is fixed on the Blower main shaft. The fan blade makes the impeller rotating in the crust driven by motor, so the waste vapors enter into the impeller center from inlet vertically along with the shaft, and pass through the fan blade. Because of the centrifugal force from the fan blade rotating, the vapors are discharged out from the Blower outlet. For the impeller working continuously, the Blower sucks and discharges the vapors continuously, in such way to complete the transportation work of vapors.

Structure Introduction

Structure Introduction

No.

Description

No.

Description

1.

Motor

3.

Main body

2.

Basement

4.

Outlet unit

Use And Maintenance

There are two lubricating points, i.e. the roller bearing at the two ends. Lubricate the roller bearing by High temperature grease. Because of high speed, the lubrication should be done once per shift, and replaced after using every half year.
The technical inspection should be done after every time stop, and also during running period.
⑴ Check the condensate water draining pipe at the Blower bottom, avoid it to be block, otherwise water logging inside the Blower crust.
⑵ During the Blower running period, check the bearing temperature is normal or not, its temperature rise should be less than 40℃.
⑶ When the v-belt is worn after long time running, replace it for the sake not affect the effects.
⑷ Check the current during the running period, it should not over the motor rated value, otherwise damage the motor. Control the value by adjusting the vapors inlet opening.

Installation collection

Blower (1) Blower (5) Blower (2) Blower (4)

Product detail pictures:

PriceList for Waste Vapor Treating Equipment For Fish Meal Plant - Fishmeal Production Line Blower – Fanxiang detail pictures


Related Product Guide:

To be a result of ours specialty and repair consciousness, our corporation has won an excellent reputation amongst customers all around the entire world for PriceList for Waste Vapor Treating Equipment For Fish Meal Plant - Fishmeal Production Line Blower – Fanxiang , The product will supply to all over the world, such as: Austria, Orlando, Florence, With top quality products, great after-sales service and warranty policy, we win trust from many overseas partner, many good feedbacks witnessed our factory's growth. With full confidence and strength, welcome customers to contact and visit us for future relationship.
  • The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
    5 Stars By Olga from Sri Lanka - 2018.06.28 19:27
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Olive from Chile - 2018.02.08 16:45
    Write your message here and send it to us