company

High definition Stainless Steel Dehumidifier Filter - Fishmeal Production Line Blower – Fanxiang

Short Description:

Product Detail

Product Tags

Related Video

Feedback (2)

Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of team building, attempting hard to boost the standard and liability consciousness of personnel customers. Our corporation successfully attained IS9001 Certification and European CE Certification of Hammer Crusher , Rising Film Evaporator , Meat & Bone Meal Plant , We have four leading products. Our products are best sold not only in the Chinese market, but also welcomed in the international market.
High definition Stainless Steel Dehumidifier Filter - Fishmeal Production Line Blower – Fanxiang Detail:

Model

Dimensions (mm)

Power (kw)

L

W

H

9-19NO8.6C

2205

1055

1510

30

9-19NO7C

2220

770

1220

15

Y5-47NO5C

1925

830

1220

11

working principle

The vapors transportation is carried out by the Blower. The impeller with several curved fan blade is fixed on the Blower main shaft. The fan blade makes the impeller rotating in the crust driven by motor, so the waste vapors enter into the impeller center from inlet vertically along with the shaft, and pass through the fan blade. Because of the centrifugal force from the fan blade rotating, the vapors are discharged out from the Blower outlet. For the impeller working continuously, the Blower sucks and discharges the vapors continuously, in such way to complete the transportation work of vapors.

Structure Introduction

Structure Introduction

No.

Description

No.

Description

1.

Motor

3.

Main body

2.

Basement

4.

Outlet unit

Use And Maintenance

There are two lubricating points, i.e. the roller bearing at the two ends. Lubricate the roller bearing by High temperature grease. Because of high speed, the lubrication should be done once per shift, and replaced after using every half year.
The technical inspection should be done after every time stop, and also during running period.
⑴ Check the condensate water draining pipe at the Blower bottom, avoid it to be block, otherwise water logging inside the Blower crust.
⑵ During the Blower running period, check the bearing temperature is normal or not, its temperature rise should be less than 40℃.
⑶ When the v-belt is worn after long time running, replace it for the sake not affect the effects.
⑷ Check the current during the running period, it should not over the motor rated value, otherwise damage the motor. Control the value by adjusting the vapors inlet opening.

Installation collection

Blower (1) Blower (5) Blower (2) Blower (4)

Product detail pictures:

High definition Stainless Steel Dehumidifier Filter - Fishmeal Production Line Blower – Fanxiang detail pictures


Related Product Guide:

Our enterprise aims to operating faithfully, serving to all of our prospects , and working in new technology and new machine frequently for High definition Stainless Steel Dehumidifier Filter - Fishmeal Production Line Blower – Fanxiang , The product will supply to all over the world, such as: Sao Paulo, Mali, Danish, Our products are mainly exported to Europe, Africa, America, the Middle East and Southeast Asia and other countries and regions. We have enjoyed a great reputation among our customers for quality products and good services.We would make friends with businessmen from at home and abroad, following the purpose of "Quality First, Reputation First, the Best Services."
  • The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Ellen from Ghana - 2018.05.15 10:52
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Samantha from Washington - 2018.06.21 17:11
    Write your message here and send it to us